The tool that helps to manage the process in a simple and intuitive mode.
AQUALOG De Visu is the tool that helps to manage the process in a simple and intuitive mode.
Thanks to the graphical interface and touchscreen display provided, you can monitor the evolving situation on the plant changing the operating parameters and sending commands to the process.
- Automation of water systems thanks to LADDER LOGIC LANGUAGE installed on board
- It can be integrated in any public or private network thanks to the wide range of local and remote communications
- Browser to present the information in Web mode
- Operational support to operators thanks to graphic interface that highlights the most important steps of the process
- It allows the fast evaluation of critical situations
CE
-20°C + 70°C
IP 20
DISPLAY |
7’’ TouchScreen |
COMMUNICATION PORTS |
1 RS232 2 RS485 (configurable as 1 RS422 port) 1 Ethernet 10/100 Mb/s 2 CANBUS 2 USB |
POWER SUPPLY |
0 - 30 V DC |
CONSUMPTION |
2 - 4 Watt (max consumption 10 Watt) |
ENVIRONMENTAL CONDITIONS |
-20°C + 70°C |
RTC CLOCK |
YES |
MEMORY |
256 MB FLASH / 128 MB RAM |
MEMORY EXPANSION |
micro SD CARD / USB |
DIGITAL INPUTS |
3 DI 10-30 V DC optoisolated and with protection ESD ± 15 KV |
DIGITAL OUTPUTS |
2 DO 10-30 V DC optoisolated and with protection ESD ± 15 KV |
ANALOGIC INPUTS |
8 AI 12 bit 0-10 V DC (4-20 mA optional) |
EXPANDIBILITY |
up to 160 DI, 64 DO, 32 AI, 16 AO |
CASE |
IP 20 |
CERTIFICATION |
CE |
ALARMS |
Signalling and managing of alarms and events generated by threshol overcoming / reaching of both physical and logical states. Messages service for the alarms notification. |
WEB FACILITIES |
WEB portal with parameter configuration and view of: REAL-TIME, ALARMS, TRENDS |
MESSAGES |
SMS / E-MAIL |
LOCAL COMMUNICATIONS: Protocols |
On RS232 / 485 port: MODBUS RTU, DLMS, OMRON FINS, IEC 62056-21 |
REMOTE COMMUNICATIONS |
TRANSMISSION MEAN: GSM / GPRS / SMS / ADSL / PPSTN / UMTS / WI-FI / F.O. for wired networks / VPN / RADIO MODEM |
PROTOCOLS and STANDARDS FOR REMOTE COMMUNICATIONS |
MODBUS RTU / SNMP / MODBUS TCP / IP / DLMS / IEC 62056-21 COMMUNICATION MODE: REAL-TIME / BATCH / FILE TRANSFER / FTP / OPC (by optional software) |
SUPERVISION |
Base Time Acquisition: 1" Base Time Storage: 1’ – 1 h Stored Samples Max Num.: 6000000 |
DATA ACQUISTION |
GPRS/3G/4G with external power supply or LoRaWAN, NB-IoT, radio modem |
COUNTERS |
Max Nr. 3 - Range: 32 bit |
AUTOMATION |
PLC EMBEDDED con LADDER LOGIC STANDARD IEC 61131-3 |
CONFIGURATION |
FROM PC USING RAINBOW CONFIGURATOR |
OPC |
COMPLIANT (by OPC SERVER) |
INTEGRATION WITH AQUAWORKS, OVERLAND Advanced and PLANT VIEW SCADA |
DIRECT BY WIZARD |
USER APPLICATION |
By LADDER languages / C / C++ in LINUX platform |
OPERATIVE SYSTEM |
LINUX EMBEDDED |